BMW hybrid-transmission control fault codes
The 69 fault codes the hybrid-transmission control can store, and what each one means. Some codes mean different things in different versions of the module; tap a code to see which applies to your car.
On: X6 (E72)
- 010218 TCM: Transmission-oil temperature too high
- 010562 TCM: Battery voltage - undervoltage
- 010563 TCM: Battery voltage - overvoltage
- 010604 TCM: TCM-internal control-module fault (RAM fault)
- 010605 TCM: TCM-internal control-module fault, ROM check faulty
- 01060B TCM: TCM-internal control-module fault (A/D converter status)
- 01060C TCM: TCM-internal control-module fault, processor, power problem
- 010634 TCM: Control module temperature too high
- 010658 TCM: Electrical supply, pressure-control valve, system pressure - short circuit to ground
- 010659 TCM: Electrical supply, pressure-control valve, system pressure - short circuit to positive
- 010667 TCM: Control module temperature sensor - power problem
- 010668 TCM: Control module temperature sensor - short circuit to ground
- 010669 TCM: Control module temperature sensor - short circuit to positive
- 010711 TCM: Transmission-oil temperature sensor - measurement-range or power problem
- 010712 TCM: Transmission-oil temperature sensor - short circuit to ground
- 010713 TCM: Transmission-oil temperature sensor - short circuit to positive
- 010721 TCM: Transmission output-speed sensor - measurement-range or power problem
- 010723 TCM: Transmission output-speed sensor - signal irregular
- 010751 TCM: Solenoid valve 1 - jammed open
- 010752 TCM: Solenoid valve 1 - jammed closed
- 010756 TCM: Solenoid valve 2 - jammed open
- 010757 TCM: Solenoid valve 2 - jammed closed
- 010776 TCM: Electronic pressure-control valve 2 - jammed open
- 010777 TCM: Electronic pressure-control valve 2 - jammed closed
- 01077C TCM: Output-speed sensor, open circuit or short circuit to ground
- 01077E TCM: Temperature-sensor system, transmission, measurement-range or plausibility fault
- 010796 TCM: Electronic pressure-control valve 3 - jammed open
- 010797 TCM: Electronic pressure-control valve 3 - jammed closed
- 01079A TCM: Clutch C1 - slip, time limit exceeded
- 01079B TCM: Clutch C2 - slip, time limit exceeded
- 01079C TCM: Clutch C3 - slip, time limit exceeded
- 01079D TCM: Clutch C4 - slip, time limit exceeded
- 010961 TCM: Electronic pressure-control valve 1, measurement-range or power problem
- 010962 TCM: Electronic pressure-control valve 1, short circuit to ground
- 010963 TCM: Electronic pressure-control valve 1, open circuit or short circuit to positive
- 010965 TCM: Electronic pressure-control valve 2, measurement-range or power problem
- 010966 TCM: Electronic pressure-control valve 2, short circuit to ground
- 010967 TCM: Electronic pressure-control valve 2, open circuit or short circuit to positive
- 010969 TCM: Electronic pressure-control valve 3, measurement-range or power problem
- 010970 TCM: Electronic pressure-control valve 3, short circuit to ground
- 010971 TCM: Electronic pressure-control valve 3, open circuit or short circuit to positive
- 010973 TCM: Solenoid valve 1 - short circuit to ground
- 010974 TCM: Solenoid valve 1 - short circuit to positive
- 010976 TCM: Solenoid valve 2 - short circuit to ground
- 010977 TCM: Solenoid valve 2 - short circuit to positive
- 0116D9 TCM: TCM-internal control-module fault, control module was not programmed
- 0116E3 TCM: TCM-internal temperature sensor (switch-on operation sensor), power problem
- 0116E4 TCM: TCM-internal temperature sensor (switch-on operation sensor), short circuit to ground
- 0116E5 TCM: TCM-internal temperature sensor (switch-on operation sensor), short circuit to positive
- 0116F3 TCM: TCM-internal control-module fault (RAM double storage)
- 011798 TCM: TCM-internal control-module fault, EEPROM write fault
- 01179A TCM: TCM-internal control-module fault, EEPROM read fault
- 011828 TCM: Electronic pressure-control valves, setpoint values incorrect or values not plausible with current operating state
- 011829 TCM: Clutch actuation, setpoint values incorrect or values not plausible with current operating state
- 01185F TCM: TCM-internal fault, immobilizer lock, currently active
- 01215C TCM: Transmission output speed not plausible with wheel speed
- 012534 TCM: Electrical input signal, ignition - short circuit to ground
- 012670 TCM: Electrical supply, pressure-control valves - short circuit to ground
- 012671 TCM: Electrical supply, pressure-control valves - short circuit to positive
- 012714 TCM: Electronic pressure-control valve 4 - jammed open
- 012715 TCM: Electronic pressure-control valve 4 - jammed closed
- 012719 TCM: Electronic pressure-control valve 4, measurement-range or power problem
- 012720 TCM: Electronic pressure-control valve 4, short circuit to ground
- 012721 TCM: Electronic pressure-control valve 4, open circuit or short circuit to positive
- 01C073 TCM, H-CAN: Communication fault
- 01C100 TCM: No message from DME control unit
- 01C293 TCM: No message (HCP hybrid master control unit)
- 01D1A8 TCM: No message (EWS status, 0x5C0) from CAS
- 01D809 TCM: No message (HIM hybrid interface module)
Coming soon